Part Number Hot Search : 
SAB80 IN74HC 8ZETE1 150EBU04 C78L27CD N4007 BC247B E1A102MR
Product Description
Full Text Search
 

To Download PMMK150D-BE Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  m e d i c a l g r a d e 1 5 0 wa t t e n c l o s e d w i t h p f c p m m k 1 5 0 e s e r i e s www.astrodyn e.com astrodyne usa: 1-800-823-8082 astrodyne europe: 353 51 561060 astrodyne pacific: 886-2-26983458 3.2w x 5.5l x 1.6h 150 watts output power single and dual outputs universal 90-264vac input 5vdc to 48vdc outputs 4000vac input to output isolation active power factor correction model number output voltage output amps (max) line regulation ripple & noise single output pmmk150s-5e 5 vdc 30 0.5% 100mv pk-pk pmmk150s-12e 12 vdc 12.5 0.5% 100mv pk-pk pmmk150s-15e 15 vdc 10 0.5% 100mv pk-pk pmmk150s-24e 24 vdc 6.3 0.5% 100mv pk-pk pmmk150s-48e 48 vdc 3.2 0.5% 100mv pk-pk dual output pmmk150d-ae 5/12 vdc 15/7 0.5/1% 50/100mv pk-pk PMMK150D-BE 5/24 vdc 15/3.5 0.5/2% 50/200mv pk-pk pmmk150d-ce 12/24 vdc 7/3.5 1/2% 100/200mv pk-pk pmmk150d-de 12/48 vdc 7/1.5 1/4% 100/400mv pk-pk
m e d i c a l g r a d e 1 5 0 wa t t e n c l o s e d w i t h p f c p m m k 1 5 0 e s e r i e s www.astrodyn e.com astrodyne usa: 1-800-823-8082 astrodyne europe: 353 51 561060 astrodyne pacific: 886-2-26983458 input spe cifications input voltage range 90-264 vac frequency range 47-63 hz power factor correction 0.96 to 0.98 inrush current, typ: 30a @ 115vac 60a @ 230vac * output spe cifications voltage and current (note 6) see selection chart line regulation (note 8) see selection chart load regulation (10%-fl, note 7) singles: 0.5%, typ duals: 3/5%, typ preset accuracy (note 9) 1%, typ dc voltage adjust (typ) 6%, typ temperature coefficient 0.05%/c ripple/noise (notes 1, 3, 10) see selection chart over voltage protection latching, auto recover after fault condition is removed * short circuit protection latching, auto recover after fault condition is removed * hold up time 20ms, typ (nom i/p, fl) gene ral spe cifications isolation (note 4) i/p-o/p: 4000vac i/p-ground: 2000vac o/p-ground: 500 vac efficiency 75%, min. switching frequency 67khz, (fixed, typical) safety ul,tuv, cb, ce environme ntal spe cifications oper. temperature -10 to +70c (see derate curve) storage temperature -25 to +85c * relative humidity 0% to +95%, non-cond * emc en55011 class b mtbf 270,000 hrs mil std 217, 25c physical sp e cifications size 3.2 x 5.5 x 1.6 construction enclosed weight 1.2 lb, (544g) notes * these are stress ratings. exposure of the devices to any of these conditions may adversely affect long term reliability. proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. all specifications are typical at nominal input, full load, and 25c unless other - wise noted astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. 1. all measurements should be made directly at the terminals of the power supply 2. all specifications typical @ 25c, unless otherwise noted, at nominal line and load. 3. ripple and noise dependent upon output voltage as specified per particular model. 4. isolation for up to 1 minute duration. 5. specified for free air convection cooling. 6. minimum load is not required for proper operation. 7. load regulation is measured by change 40% of measured output load from 60% full load, with the other output set to 60% full load. 8. line regulation measured from 90-264vac. 100vac minimum required for full load start. 9. preset accuracy measured at nominal load, 120vac input. 10. o/p noise measured directly at the pins/terminals at nominal load, 0.1uf bypass and 47uf electrolytic, pk-pk @ 20mhz bandwidth.
m e d i c a l g r a d e 1 5 0 wa t t e n c l o s e d w i t h p f c p m m k 1 5 0 e s e r i e s www.astrodyn e.com astrodyne usa: 1-800-823-8082 astrodyne europe: 353 51 561060 astrodyne pacific: 886-2-26983458 me chanical dimensions 5. 70 mm [0 .2 24 in ] 65 .7 0 m m [2 .5 87 in ] 13 4. 00 mm [5 .2 76 in ] 13 9. 70 mm [5 .5 00 in ] 1 5 . 1 0 m m [ 0 . 5 9 4 i n ] 2 8 . 2 0 m m [ 1 . 1 1 0 i n ] 6 5 . 3 0 m m [ 2 . 5 7 1 i n ] 8 0 . 4 0 m m [ 3 . 1 6 5 i n ] 1 2 . 0 0 m m [ 0 . 4 7 2 i n ] 2 4 . 0 0 m m [ 0 . 9 4 5 i n ] m3 x0 .5 - 6 h 7_ ( t he le ng th : 3 mm ) 40.60 mm [1.598 in ]
m e d i c a l g r a d e 1 5 0 wa t t e n c l o s e d w i t h p f c p m m k 1 5 0 e s e r i e s www.astrodyn e.com astrodyne usa: 1-800-823-8082 astrodyne europe: 353 51 561060 astrodyne pacific: 886-2-26983458 output de rating curve - single output output de rating curve - dual output 1. forced air colling 10 cfm 2. free air convection - open frame, u-channel 3. free air convection - enclosed


▲Up To Search▲   

 
Price & Availability of PMMK150D-BE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X